skip to main content


Search for: All records

Creators/Authors contains: "De Mauro, G."

Note: When clicking on a Digital Object Identifier (DOI) number, you will be taken to an external site maintained by the publisher. Some full text articles may not yet be available without a charge during the embargo (administrative interval).
What is a DOI Number?

Some links on this page may take you to non-federal websites. Their policies may differ from this site.

  1. Abstract We present a measurement of the cosmic-ray spectrum above 100 PeV using the part of the surface detector of the Pierre Auger Observatory that has a spacing of 750 m. An inflection of the spectrum is observed, confirming the presence of the so-called second-knee feature. The spectrum is then combined with that of the 1500 m array to produce a single measurement of the flux, linking this spectral feature with the three additional breaks at the highest energies. The combined spectrum, with an energy scale set calorimetrically via fluorescence telescopes and using a single detector type, results in the most statistically and systematically precise measurement of spectral breaks yet obtained. These measurements are critical for furthering our understanding of the highest energy cosmic rays. 
    more » « less
  2. null (Ed.)
  3. null (Ed.)
  4. null (Ed.)
  5. null (Ed.)
  6. null (Ed.)
  7. null (Ed.)
  8. null (Ed.)
  9. null (Ed.)
  10. null (Ed.)
    Abstract The hybrid design of the Pierre Auger Observatory allows for the measurement of the properties of extensive air showers initiated by ultra-high energy cosmic rays with unprecedented precision. By using an array of prototype underground muon detectors, we have performed the first direct measurement, by the Auger Collaboration, of the muon content of air showers between $$2\times 10^{17}$$ 2 × 10 17 and $$2\times 10^{18}$$ 2 × 10 18 eV. We have studied the energy evolution of the attenuation-corrected muon density, and compared it to predictions from air shower simulations. The observed densities are found to be larger than those predicted by models. We quantify this discrepancy by combining the measurements from the muon detector with those from the Auger fluorescence detector at $$10^{{17.5}}\, {\mathrm{eV}} $$ 10 17.5 eV and $$10^{{18}}\, {\mathrm{eV}} $$ 10 18 eV . We find that, for the models to explain the data, an increase in the muon density of $$38\%$$ 38 % $$\pm 4\% (12\%)$$ ± 4 % ( 12 % ) $$\pm {}^{21\%}_{18\%}$$ ± 18 % 21 % for EPOS-LHC , and of $$50\% (53\%)$$ 50 % ( 53 % ) $$\pm 4\% (13\%)$$ ± 4 % ( 13 % ) $$\pm {}^{23\%}_{20\%}$$ ± 20 % 23 % for QGSJetII-04 , is respectively needed. 
    more » « less